PLASTIC PIPES 2024                                                                   Industry news


            THE APPLICATION OF PLASTIC


            PIPES IN THE DESIGN OF HIGH	RISE


            BUILDINGS HAS BEEN POSSIBLE




            rapts.ru



                he Ministry of Construction ap-
            T proved Amendment No. 1 to SP
            253.1325800.2016 “Code of Rules. Engi-
            neering systems of high-rise buildings”,
            which allows the use of plastic pipes in
            the design of high-rise buildings up to 100
            meters high.
               In the previous version of the docu-
            ment, clause 10.9 stated:
               Main pipelines and risers of cold and
            hot water supply should, as a rule, be pro-
            vided from metal pipes: copper according
            to GOST R 52318, steel according to GOST
            3262 with anti-corrosion coating on the
            internal and external surfaces, galva-
            nized, stainless steel.
               Clause 10.9. has been supplemented
            with the following enumeration now:
               It is allowed to use plastic pipes in
            buildings up to 100 m high, while it is nec-
            essary to install thermal expansion com-
            pensation devices on the risers and cor-
            responding fixed fastenings on each floor.
               In the previous version of the docu-
            ment, clause 11.3 was worded as follows:
               Pipes for domestic sewerage should be
            made of high-strength cast-iron socket-
            less pipes. Horizontal piping within the
            serviced  floor  is  allowed  to  be  made  of
            polymer pipes.
               Clause 11.3. has been supplemented
            with a paragraph in the following wording   The approval of these changes took
            now:                               place with the assistance of the Pipe-
               It is permissible to use risers made of   line Systems Manufacturers Association
            plastic pipes in buildings up to 100 m high,   (PSMA), in close cooperation with the Min-
            while it is necessary to perform tempera-  istry of Construction of Russia and Tech-
            ture expansion compensation devices   nical Committee (TC) 465 “Construction”.
            and  corresponding  fixed  fasteners  on   The text of the document can be found
            each  floor.   loor  intersections  should  be   on the Ministry of Construction website
            equipped with fire-resistant sleeves.  via this link.